Model
XDC2500-12
48 V Voltage range
24 V - 36 / 48 / 54 V - 57 V
12 V Voltage range
8 V - 8.5 / 14 / 15.5 V - 16 V
Max. Rated Power
Buck: 2.5 kW (178 A @14 V), Boost: 2 kW (41 A @48 V)
Buck mode: The derating factor is 15.5 V - 16 V , 8.5 V-8 V corresponding to 100% - 0 load
Boost mode: The derating factor is 54 V - 57 V, 36 V-24 V corresponding to 100% - 0 load
Over-temperature protection range
248℉ (120℃)
CAN communication
CAN communication
Wake-up type
KL15
Precharge time
Once pre-charge instruction is received, the 48 V side busbar capacitor voltage is expanded from 12 V to rated 48 V set by the controller in 150 ms.
Working temperature range
1. At temperature below -40℉ (-40℃), the output is turned off. 2. At temperature between 104℉ - 140℉ (40℃ - 60℃), full power output is reached. 3. At temperature between 140℉ - 185℉ (60℃ - 85℃), linear reduced output of 2,500 W - 0 W is provided. 4. At temperature above 185℉ (85℃), output is turned off.
Ingress protection rating
IP67
Weight
< 6.6 lbs (3 kg)
Dimension
9.4 x 6.9 x 3.0 inch (238 x 175 x 75 mm)
All data are based on ROYPOW standard test procedures. Actual performance may vary according to local conditions